Technical details for cover installation

1. Standard for Lids
Standard for caps valid in Israel TI-489 489-2.1/2.2/2.3/2.4/1.5/2.5/2.6 Date: 8/2016
This standard is the same as the European Standard (June 2015) EN-124-1/2/3/4/5/6.

2. Choosing the Lid
The main and most useful types are: D400, C250, B125, A15.
(Other types such as E600, F900 for exceptional loads and special uses such as ports and airports)
Type A15: Pedestrians and cyclists only.
Type B125: sidewalks, pedestrian zones
Type C250: The road area that is not far from the language stone is more than 0.50 meters.
Mainly refers to rectangular drainage nets for receptors that are attached to the language stone.
Type D400: Roads, pedestrian streets, harsh margins and parking areas for all types of vehicles.
Type E600: Sea ports and industrial zones.
Type F900: Airports.

Type Designation, usage areas Test Load KN Group
A15 Pedestrians and cyclists only 15 1
B125 Sidewalks, parking lots or parking spaces, pedestrian areas 125 2
C250 Adjacent to a language stone is no longer than 0.50 m into the road.
Mainly rectangular drainage nets consisting of receptors that are attached to the language stone.
250 3
D400 Roads, pedestrian streets, harsh roads and parking areas. 400 4
E600 Sea ports and industrial zones. 600 5
F900 Airports. 900 6

* Cover from Group 1, type A15, to areas that can only be used for pedestrians and cyclists.

3. Sorting and Marking
From the species cover for drainage vents and cover for control chambers as follows:
F900, E600, D400, C250, B125, A15

4. Installation Locations
Type of lid that is used to develop a drainage or control cell, depending on the installation location.
The installation places have been divided into 4 groups as follows.
The painting describes the placement of some of these groups on the road.
Next to each group number, the recommended quota for use of the group is specified.
The responsibility for choosing the right type rests on the planner. In the case of doubt, it is advisable to choose the stronger type.

Group 1 (at least type A15)
Areas that can only be used for pedestrians and bicyclists.

Group 2 (at least type B125)
Sidewalks, pedestrian areas and similar areas, parking lots or parking spaces (parking decks)

Group 3 (at least type C250)
From the drainage canals in the road, along the sidewalk, which are not more prominent than 0.5
M from the sidewalk to the road, and no more than 0.2 m from the curb to the sidewalk.

Group 4 (at least type D400)
Road driving routes (including pedestrian streets) are difficult margins and parking areas for all types of vehicles.

Group 5 (at least type E600)
Industrial zones and sea ports

Group 6 (at least type F900)
Airports

5. Cut through